Must-Knows
FRC Electrical Must-Knows:
|
COMMON TERMS |
|
|
TERM |
DEFINITION |
|
CAN |
"CONTROL AREA NETWORK" A COMMUNICATION PROTOCOL USED BY DEVICES FOR BIDIRECTIONAL COMMUNICATION ON A CHAIN. COMMONLY FOUND AS A 22AWG GREEN AND YELLOW TWISTED PAIR. MUST BE TERMINATED USING 1200 RESISTOR BETWEEN HIGH AND LOW (YELLOW AND GREEN RESPECTIVELY) |
|
PDH |
"POWER DISTRIBUTION HUB" WHICH CONNECTS DIRECTLY TO BREAKER AND BATTERY AND DISTRIBUTES POWER. BREAKERS AND FUSES FOR OVERCURRENT PROTECTION. CONNECTS TO CAN FOR DIAGNOSTIC INFORMATION |
|
ROBORIO |
MAIN ROBOT COMPUTER |
|
RSL |
"ROBOT SIGNAL LIGHT" USED TO INDICATE STATUS OF ROBOT |
|
VRM |
VOLTAGE REGULATOR MODULE" USED TO SUPPLY SENSORS AND DEVICES WITH REGULATED 12V OR 5V POWER RATHER THAN RAW BATTERY VOLTAGE |
|
PWM |
"PULSE-WIDTH MODULATION" SIMPLE UNIDIRECTIONAL SIGNALING USED TO TRANSMIT A VALUE BETWEEN 0-100% |
|
AWG |
"AMERICAN WIRE GAUGE" AMERICAN STANDARD FOR WIRE DIAMETER. PRONOUNCED GAUGE. SMALLER NUMBER MEANS LARGER DIAMETER, DOUBLING WIRE DECREASES AWG BY 3 |
|
FUSE |
OVERCURRENT PROTECTION DEVICE WITH COLORFUL PLASTIC HOUSING. PERMANANTLY DAMAGED WHEN TRIPPED |
|
BREAKER |
OVERCURRENT PROTECTION DEVICE WITH COLORFUL METAL HOUsING. AUTOMATiCALLY RESETS AFTER COOLING WHEN TRIPPED, TRIP INDICATED BY BLINKING LIGHT ON PDH |
|
FALCON 500 |
BRUSHLESS MOTOR WITH BUILT IN MOTOR CONTROLLER. CONTROLLED OVER CAN |
|
KRAKEN X60 |
NEWER BRUSHLESS MOTOR WITH BUILT IN MOTOR CONTROLLER. CONTROLLED OVER CAN, REPLACABLE LEADS |
|
SPARK MAX |
STANDALONE MOTOR CONTROLLER, COMPATIBLE WITH WIDE RANGE OF BRUSHED AND BRUSHLESS MOTORS |